Vents

| Ventline | Jensen | Elixir | Refrigerator | Plumbing | Notes |

Roof vents include the crank-up vent/skylight, refrigerator vent, and plumbing vents. Most crank-ups fit into or over a 14" square opening this is the "nominal" size, the actual vent sizes vary slightly but most are approximately 15 /12" square on the outside. There are or have been several brands, the most common in current use being Ventline, Jensen, and Elixir. Some tent campers have a 9" square vent.

The easiest method of identification is the hinge style.

Ventline features a sheet metal hinge with a bendable tab at each end.

Jensen has a "piano" style hinge with a screw in each end which are removed to take out the hinge pin. Jensen also has a newer model that uses no pin.

Elixir vent hinges consist of a tubular extruded aluminum shape with a slot and a screw in each end which when removed allows the vent cover to slide off the mating surface.

ventline vent hinge
Ventline Roof Vent
Translucent plastic dome, with metal framed base, removable screen. Fits standard 14" square opening. Order inside trim ring separately for up to 4" roof thickness. The photo, above right, shows the hinge style, which has a metal tab on each end, which is bent to keep the vent in its mating track. Available in white or smoke.

Ventline Vents and vent parts
  order # description price wt.  

  V554-1 Ventline cover - white, fits V2012-1, V2092-1, V2094 $13.50 2.0

V2092-901 Ventline vent - white w/o trim ring $27.50 4.4

V2094 Ventline 12 volt power vent - white w/o trim ring $70.50 5.4

VA445-33 trim ring, radius corner, white, 1 1/8" vertical leg $4.79 1.0

VA445-34 trim ring, radius corner, white, 2 1/8" vertical leg $4.79 1.0

VA445-35 trim ring, radius corner, white, 3 1/8" vertical leg $4.79 1.0

VA445-36 trim ring, radius corner, white, 4 1/8" vertical leg $4.79 1.0

VK01 vent installation kit, 6 ft butyl tape, 32 screws $3.29 0.9

Ventline has discontinued the V2012-1 vents w/the square cornered screen frame and trim ring. Vents and trims are limited to quantity on hand.The vents that replace these (V2092-1) have a radius corner screen frame and trim ring. We are told that the radius trim ring will work with the square corner screen frame. Note that from the roof flange up, these vents are identical. The difference is in the screen and frame.

  V100-x trim rings with square corners are no longer available use VA445-xx      

V115-4 Ventline operator - std $7.99 0.4

VA101-1 gasket - vent cover to frame - Ventline $5.99 0.2

  VA164 Ventline 12 volt fan motor -
flat sided shaft is NLA use VC468-1
NLA   NLA

  VC468-1 Ventline 12 volt fan motor - round shaft $20.50 0.5

  VA163 Ventline fan blade for VA164 motor is
NLA use VC466
NLA   NLA

  VC466 Ventline fan blade w/round bore $6.99 0.2
Top Jensen roof vents
Injection molded plastic roof vent, removable screen, fits standard 14" square opening, trim ring fits up to 3 1/2" thick roof. Available with both plastic or metal frame with radius corners and white covers. The Jensen vent in most common use has a piano style hinge.
Jensen Vents and vent parts
  order # description price wt.  

60752  Jensen roof vent 14" sq. metal base w/trim ring $54.50 6.0

63110  Jensen vent cover - white - w/o slide bar $15.50 2.4

7291WH  Jensen/Elixir vent cover,
 white - w/new style hinge,
 snap on - no pin
$20.50 2.4

VK01  vent installation kit, 6 ft butyl tape,
  32 screws
$3.29 0.9

 
Top Elixir roof vents

Plastic framed vent fits standard 14" square opening, removable screen, available in white and smoke. Hinge is a tubular extruded aluminum shape with a slot and a screw in each end.
Elixir Vents and vent parts
  order # description price wt.

63116 Elixir vent cover - white $15.50 2.4

63118 Elixir vent cover - smoke $15.50 2.4

18511G-1 9" x 9" vent assembly, white w/trim ring
requires 9.5" rough opening
limited to stock on hand
$46.75 2.0

17511G-1 9" x 9" vent assembly, colonial white w/trim ring
requires 9.5" rough opening
$46.75 2.0

VK01 vent installation kit, 6 ft butyl tape, 32 screws $3.29 0.9

Roof vent notes:

The condition of roof vent covers should be checked annually, covers that have a dull lifeless look should be replaced, when this point is reached they are generally quite brittle. A cover in good condition usually has a shiny appearance. Plastic framed roof vents should be inspected carefully for cracks in the frame, both on the roof and from inside, with the inside trim ring removed. If any cracks are observed the vent should be replaced.
 